(Summary description)When the pressure and flow of the air pump drop, cut off the power supply of the air pump, check whether there is something blocked in the air inlet, check the air inlet filter, do not remove the filter, otherwise debris will be sucked into the air pump and cause damage.
Industrial gas pump Manufacturers china introduces air volume adjustment and troubleshooting knowledge of air pumps
(Summary description)When the pressure and flow of the air pump drop, cut off the power supply of the air pump, check whether there is something blocked in the air inlet, check the air inlet filter, do not remove the filter, otherwise debris will be sucked into the air pump and cause damage.
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2021-12-16 11:39
- Views:
How much do you know about the air volume adjustment and fault maintenance of the air pump? The following editor of Industrial gas pump Manufacturers china will show you a brief look!
When the pressure and flow of the air pump drop, cut off the power supply of the air pump, check whether there is something blocked in the air inlet, check the air inlet filter, do not remove the filter, otherwise debris will be sucked into the air pump and cause damage. There are debris inside the air pump, which causes the rubber skin to withstand the electromagnet, causing the electromagnet to fail to restore its position. We can open the casing of the vortex air pump to clean up the internal debris. Drill a small hole in the rubber to eliminate the adsorption effect caused by negative pressure. The lack of phase or the wrong direction of rotation of the motor is also a cause of this type of failure.
Introduction from the editor of Industrial gas pump Manufacturers china: We should check and reconnect the power supply. If the motor burns out, replace the motor of the same model. For single-phase motors, check whether the capacitors are intact and the wiring is correct. When the body temperature of the air pump increases, check whether the air inlet is blocked, clean the air inlet filter, but not remove it, otherwise it will suck in debris and damage the mechanical equipment. Please properly maintain the working gap of the air pump. Secondly, check for sundries in the machine, open the shell, and clean up the inner sundries. The air volume of the air pump is marked at a frequency of 50hz, and the air volume can be large or small by changing its speed.
After the speed of the air pump is changed, the pressure value is also different, so the adjustment process depends on the actual usage; in this case, a certain energy saving effect can also be achieved, which is also a commonly used method. The air volume adjustment is smaller, and the air deflation method can be used. By installing a valve device such as a three-way ball valve, it is enough to make a certain port. This method is simple to operate, without any equipment cost, and can be directly operated on site. If there is no wind at the air outlet of the air pump, the air pump will not turn.
The above is what the editor of Industrial gas pump Manufacturers china tells: about the air volume adjustment and fault maintenance knowledge of the air pump.