Industrial gas pump introduction to the use and installation of vortex gas pump
- Categories:Industrial gas pump
- Author:
- Origin:
- Time of issue:2022-09-15 16:03
- Views:
(Summary description)The vortex air pump should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
Industrial gas pump introduction to the use and installation of vortex gas pump
(Summary description)The vortex air pump should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
- Categories:Industrial gas pump
- Author:
- Origin:
- Time of issue:2022-09-15 16:03
- Views:
1. The vortex air pump should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
2. The rotation direction of the impeller of the vortex air pump must be the same as the direction of the arrow marked on the fan casing.
3. When the high-pressure vortex fan is working, the working pressure should not be greater than 8kpa, so as to avoid the excessive heat of the fan and the overcurrent of the motor causing damage to the air pump.
4. Except for the two bearings of the motor rotor, the other parts of the vortex fan have no direct contact conflict.
5. The filter screen and muffler equipment at the inlet and outlet ends of the vortex air pump should be cleaned in time according to the situation, so as not to block and affect the use.
6. The external connection of the air inlet and outlet of the vortex air pump must be connected by a hose.
7. Replacement of the bearing of the vortex air pump: The replacement of the bearing must be operated by someone who understands the repair work. When disassembling, do not pry the impeller hard, use a special puller to pull it out, and do not miss the adjustment gasket, so as not to affect the clearance that has been adjusted before leaving the factory.
8. It is strictly forbidden for solids, liquids and corrosive gases to enter the pump body of the high-pressure vortex air pump.